- Contact Person : Mr. Wu Peter
- Company Name : Green Power Electronics (Shenzhen) Co., Ltd.
- Tel : 86-0755-29172521-8003
- Fax : 86-0755-27337232
- Address : Guangdong,Shenzhen,Building NO. 26, Xingwei the Third Industrial Park, Fenghuang Village, Fuyong Town, Baoan District, Shenzhen City
- Country/Region : China
- Zip : 518103
ups 200kva
GP33-160Kva 208v
The True Online double conversion technology provides clean and safe energy to all devices on your network, communication systems and critical loads. The Digital Signal Processing (DSP) technology allows the UPS take faster response to different kind of power problems, keeping the load working. His advance battery charging system allows the UPS to offer long backup time, short recharge, the temperature compensation system helps to increase the life of batteries. His simplified circuit controls makes our products smaller, lighter and increase the confiability, reducing the number of internal componets.
Main Features:
•TRUE ON LINE DOUBLE CONVERSION Technology
•100% microcontrolled by DSP
•N + 1, parallel and redundant
•High efficiency > 92%
•Dual Input (optional)
•100% unbalanced load allowed
•Cold start function
•Smart battery control function
•Generator compatible
Specifications:
Model | GP33-160Kva 208v |
Capacity | 160KVA |
Type | Tower |
Input | |
Voltage(*) | 208 ± 20% / 5 wires (3 lines + Neutral + Ground) |
Freq | 50 / 60Hz ± 10% autosensing |
Power Factor / Filters | >0.98 / EMI, RFI |
Dual input | Optional |
Output | |
Voltage (*) | 208 ± 20% / 5 wires (3 lines + Neutral + Ground) |
Frequency | 50Hz/60 Hz ± 0.1% |
Efficiency / transfer time | AC/AC >92% / 0 ms |
wave form | Sine Wave |
Voltage T.H.D. | <2% with linear load, <5% with nonlinear load |
Crest factor / power factor | 3:1 / 0.9 |
Technology | True On-Line double conversion controlled by microcontroller |
Overload recovery | automatically transfer to UPS mode |
isolation transformer | On UPS mode, (on bypass mode is optional) |
Battery | |
Battery type | VRLA (Valve Regulated Lead Acid) not included |
DC Voltage | 480Vdc |
Recharge time | 4 hours up to 90% |
Battery test | Auto-test, Transfer to battery mode adjustable |
Protections | |
hardware protections | input Breaker, Output Breaker, Battery breaker, Bypass breaker; DC Fuse, Fan, redundant power supply; temperature sensor, EPO (Emergency Power Off), audible alarms |
Software Protections | Discharging batteries, Battery charger working, Inverter working, Emergency Power Off, manual Shutdown, Bypass SCR fail, bypass sequence fail, Bypass over the limit, critical overload, battery exhausted, low output voltage, high output voltage, DC fuse open, %v power supply fail, 13.5 v power supply fail, inverter overvoltage, 200% overload on each line, transfer fail, inverter voltage out of range, voltage between neutral and ground high, UPS on Bypass mode, Bypass frequency out of range. |
Bypass | solid state, |
Overload | 125% for 10 min, 150% for 30 sec, 1000% for 1 cycle. |
EPO | EPO local and/or remote |
Display | LCD |
LED´s diagram | included |
Communication | serial port RS-232, SNMP(RJ-45) (SNMP card not included) |
Environment | |
Elevation/ humidity | 1.700 m.o.s.l without derrating / 0 a 95% non condensate |
temperature / noise | 0° a 40° C / <60 dB @ 1,5 m. |
Dimension | |
Dimension | Ask for information |
Weight (without batteries) |
ups 200kva